During I involved in Oil & Gas Industry, i found some company were struggled in this industry.
Below I list the company :
1. Yokogawa Kontrol System. (DCS) Puchong
2. Yokogawa Saftey. (SDS/SIS/IPS/FGS) Puchong
3. Trisystem Engineering Sdn. Bhd (SIS/FGS/SDS/IPS) Shah ALam
4. Emerson. (DCS/SIS/FGS/SDS/IPS)
5. Tanjung
6. ABB
7. Foxboro
8. Honeywell
9. Heaven
I experienced with Yokogawa and Trisystem.
For future, i will look to another company and new challenge.
Sunday, November 16, 2008
Tuesday, November 11, 2008
Tuesday, November 4, 2008
CHECKLIST PREPARATIONS GO TO OFFSHORE
CHECKLIST PREPARATIONS GO TO OFFSHORE
Scope of preparation
1. Mental & physical
2. Knowledge
2.1 Study latest logic
2.2 Study overall system
2.3 Study what to be done
2.4 Procedures to download all or download change
3. Technical skill
4. Cloths (Offshore)
4.1 Coverall
4.2 Goggles
4.3
5. Tools
5.1 1.0mm (100m) white cable
5.2 Ferrules. What types?
5.3 Clamping ferrules
6. Financial (Petty Cash)
7. Family
8. Report form
9. Activities Form
10. Claim form
11. Travel (Limosin)
12. Communication (i-Talks)
Scope of preparation
1. Mental & physical
2. Knowledge
2.1 Study latest logic
2.2 Study overall system
2.3 Study what to be done
2.4 Procedures to download all or download change
3. Technical skill
4. Cloths (Offshore)
4.1 Coverall
4.2 Goggles
4.3
5. Tools
5.1 1.0mm (100m) white cable
5.2 Ferrules. What types?
5.3 Clamping ferrules
6. Financial (Petty Cash)
7. Family
8. Report form
9. Activities Form
10. Claim form
11. Travel (Limosin)
12. Communication (i-Talks)
Electrical Apparatus in Hazardous Area Crash Course
Ada course hari ni kat office Electrical Apparatus in Hazardous Area Crash Course.
Based on my survey, I found that a lot of engineers cannot differentiate the differences between Ex'n' and Ex'e'. Also, only a few engineers realise that IEC requires the minimum of IP54 for cabinet that houses certified electrical apparatus to be installed in Zone 2 or even in Zone 1. The general mis-understanding is that we are required to use at least an IP65 cabinet.
To enhance the understanding on the electrical apparatus in hazardous area, I will conduct a crash course on that topic. The details of the crash course are as follows:
Date: Next week on Tuesday, 4/11/08
Time: 10:00am~12:30pm
Venue: Conference Room
The attendance is compulsory for the engineers and technicians from the TSE's Engineering Division (Project Department and CSD) including the UTP trainees. Other TriSystems' engineers and members are also welcomed to attend this 2.5-hour crash course.
Based on my survey, I found that a lot of engineers cannot differentiate the differences between Ex'n' and Ex'e'. Also, only a few engineers realise that IEC requires the minimum of IP54 for cabinet that houses certified electrical apparatus to be installed in Zone 2 or even in Zone 1. The general mis-understanding is that we are required to use at least an IP65 cabinet.
To enhance the understanding on the electrical apparatus in hazardous area, I will conduct a crash course on that topic. The details of the crash course are as follows:
Date: Next week on Tuesday, 4/11/08
Time: 10:00am~12:30pm
Venue: Conference Room
The attendance is compulsory for the engineers and technicians from the TSE's Engineering Division (Project Department and CSD) including the UTP trainees. Other TriSystems' engineers and members are also welcomed to attend this 2.5-hour crash course.
Monday, November 3, 2008
Subscribe to:
Posts (Atom)